Arria® V Device Handbook: Volume 2: Transceivers

ID 683573
Date 5/29/2020
Public
Document Table of Contents

1.1.4.5.3. Calibration Block Boundary

There is one calibration block in each quadrant of the device.

The calibration block also uses the reconfiguration controller clock (mgmt_clk_clk ). This puts a restriction on the number of different reconfiguration clock sources that can be used in the design. All the transceiver channels controlled by a single calibration block must be connected to the same reconfiguration clock source.

Note: You can connect multiple reconfiguration controllers to the same clock source.
Table 15.  Transceiver Calibration Block Boundary for Arria V GZ Devices
Arria V GZ Device Package Total Number of Transceiver channels in device Total Number of Transceiver Channels per Side Number of Contiguous Transceiver Channels Controlled by the Top Calibration Block (counting from top to bottom) Number of Contiguous Transceiver Channels Controlled by the Bottom Calibration Block (counting from bottom to top)
5AGZC3 EH29 12 6 (Left) / 6 (Right) 3 3
HF35 24 12 (Left) / 12 (Right) 6 6
KF40 36 18 (Left) / 18 (Right) 9 9
5AGZI3 EH29 12 6 (Left) / 6 (Right) 3 3
HF35 24 12 (Left) / 12 (Right) 6 6
KF40 36 18 (Left) / 18 (Right) 9 9
5AGZC4 EH29 12 6 (Left) / 6 (Right) 3 3
HF35 24 12 (Left) / 12 (Right) 6 6
KF40 36 18 (Left) / 18 (Right) 9 9
5AGZI4 EH29 12 6 (Left) / 6 (Right) 6 6
HF35 24 12 (Left) / 12 (Right) 12 12
KF40 36 18 (Left) / 18 (Right) 9 9