Visible to Intel only — GUID: lmq1631699241131
Ixiasoft
1. Agilex™ 7 SEU Mitigation Overview
2. Agilex™ 7 CRAM Error Mitigation
3. Secure Device Manager ECC and SmartVID Errors Detection
4. Agilex™ 7 SEU Mitigation Implementation Guides
5. IP and Software References
6. Agilex™ 7 SEU Mitigation User Guide Archives
7. Document Revision History for the Agilex™ 7 SEU Mitigation User Guide
4.6.1. Launching and Setting Up the Fault Injection Debugger
4.6.2. Configuring Your Device using a Software Object File (.sof)
4.6.3. Constraining Regions for Fault Injection
4.6.4. Injecting Errors to Random Locations
4.6.5. Injecting Errors to Specific Locations
4.6.6. Injecting Double Adjacent Errors
4.6.7. Injecting SDM ECC Errors
4.6.8. Analyzing SEU or SDM ECC Errors Using Signal Tap
Visible to Intel only — GUID: lmq1631699241131
Ixiasoft
3.3. SDM ECC and SmartVID Errors Signals Behavior
When the Agilex™ 7 device detects an SDM ECC or SmartVID error, the generic_sdm_valid_out signal of the Advanced SEU Detection IP goes high for one clock cycle.
Always monitor the generic_sdm_valid_out signal. When the generic_sdm_valid_out signal goes high, retrieve the SDM ECC error message content from the generic_sdm_data_out signal of the Advanced SEU Detection IP.
For an example of analyzing ECC errors with Signal Tap after injecting the error and retrieving the error data, refer to the related information.