6.4.2. Data Bit-Order for Data Interface

Figure 32. Data Bit-Order ConventionThis figure shows the bit-order convention for the din, dout and oe data signals.


  • If the data bus size value is SIZE, the LSB is at the right-most position.
  • If the data bus size value is 2 × SIZE, the bus is made of two words of SIZE.
  • If the data bus size value is 4 × SIZE, the bus is made of four words of SIZE.
  • The LSB is in the right-most position of each word.