AN 896: Multi-Rail Power Sequencer and Monitor Reference Design

ID 683778
Date 3/15/2024
Public
Document Table of Contents

2.3.7.1. POR Pulse (POR_Pulse)

Creates a reset pulse immediately after configuration for 16 clock cycles. This can be set to any value from 2 to 64 clock cycles.