Agilex™ 7 F-Series and I-Series Known Issue List

ID 683584
Date 3/13/2025
Public
Document Table of Contents

2.1.1.6. FGT PAM4 Bounding Solution

Description

The FGT receiver is not compliant with the electrical specifications for the following industry standards when used with PAM4 modulation:
  • FGT 53G C2M
  • FGT 53G C2C
  • FGT 58G LR
  • FGT 56G LR
  • FGT 36G-53G LR
  • FGT 58G VSR
  • FGT 56G VSR
  • FGT 36G-53G VSR
  • FGT 58G MR
  • FGT 56G MR
  • FGT 36G-53G MR
  • FGT 53G CR without ANLT
  • FGT 53G CR with ANLT
  • FGT 53G KR without ANLT
  • FGT 53G KR with ANLT

Workaround

For protocols that require FGT PAM4 usage, in order to ensure BER compliance, please contact Altera Customer Support and refer to the case 14023487435.

If the application fits within a Bounding Solution, bit error ratio performance is achieved with a margin over the full voltage and temperature range specifications for the device.

Status

Table 8.  Device Status Table
Devices Affected Planned Fix
  • AGFxxxxxxxxxxxx
  • AGIxxxxxxxxxxxx
None