6.6.8. Transceiver Reconfiguration Interface
You can reconfigure the transceiver to accept a single or dual reference clocks depending on the design variant.
Devices | Data Rate | Reference Clock Frequency | Description |
---|---|---|---|
Intel FPGA Cyclone 10, Intel FPGA Arria 10 | RBR, HBR, HBR2, HBR3 | 135 MHz | Single reference clock for all HBR* data rates |
Intel FPGA Stratix 10 | RBR, HBR, HBR2, HBR3 | 135 MHz | Reference clock switching required between HBR* rate and UHBR* rate |
UHBR10, UHBR20 | 100 MHz | ||
Intel FPGA Agilex | RBR, HBR, HBR2, HBR3, UHBR10 | 150 MHz | Single reference clock for all HBR* and UHBR* data rates |
*Refer to respective Design Example User Guides for more details.
During run-time, you can reconfigure the transceiver to operate in either one of the bit rates by changing RX CDR PLLs divider ratio.