Visible to Intel only — GUID: mwh1409958312662
Ixiasoft
1.1. Compilation Overview
1.2. Using the Node Finder
1.3. Design Analysis & Elaboration
1.4. Design Synthesis
1.5. Design Place and Route
1.6. Incremental Optimization Flow
1.7. Fast Forward Compilation Flow
1.8. Full Compilation Flow
1.9. HSSI Dual Simplex IP Generation Flow
1.10. Exporting Compilation Results
1.11. Integrating Other EDA Tools
1.12. Compiler Optimization Techniques
1.13. Compilation Monitoring Mode
1.14. Synthesis Language Support
1.15. Synthesis Settings Reference
1.16. Fitter Settings Reference
1.17. Design Compilation Revision History
1.4.3.1. Registering the SDC-on-RTL SDC File
1.4.3.2. Applying the SDC-on-RTL Constraints
1.4.3.3. Inspecting SDC-on-RTL Constraints
1.4.3.4. Creating Constraints in SDC-on-RTL SDC Files
1.4.3.5. Using Entity-Based SDC-on-RTL Constraints
1.4.3.6. Types of SDC Files Used in the Quartus® Prime Software
1.4.3.7. Example: Using SDC-on-RTL Features
1.10.1. Exporting a Version-Compatible Compilation Database
1.10.2. Importing a Version-Compatible Compilation Database
1.10.3. Creating a Design Partition
1.10.4. Exporting a Design Partition
1.10.5. Reusing a Design Partition
1.10.6. Viewing Quartus Database File Information
1.10.7. Clearing Compilation Results
1.12.1. Compiler Optimization Modes
1.12.2. Precompiled Component (PCC) Generation Stage
1.12.3. Compilation on a Compute Farm
1.12.4. Allow Register Retiming
1.12.5. Automatic Gated Clock Conversion
1.12.6. Enable Intermediate Fitter Snapshots
1.12.7. Fast Preserve Option
1.12.8. Fractal Synthesis Optimization
2.1. Factors Affecting Compilation Results
2.2. Strategies to Reduce the Overall Compilation Time
2.3. Reducing Synthesis Time and Synthesis Netlist Optimization Time
2.4. Reducing Placement Time
2.5. Reducing Routing Time
2.6. Reducing Static Timing Analysis Time
2.7. Setting Process Priority
2.8. Reducing Compilation Time Revision History
Visible to Intel only — GUID: mwh1409958312662
Ixiasoft
2.1. Factors Affecting Compilation Results
Almost any change to the following project settings, hardware, or software can impact the results from one compilation to the next.
- Project Files—changes to project settings (.qsf, quartus2.ini), design files, and timing constraints (.sdc) can change the results.
- Any setting that changes the number of processors during compilation can impact compilation results.
- Hardware—CPU architecture, not including hard disk or memory size differences. Windows XP x32 results are not identical to Windows XP x64 results. Linux x86 results is not identical to Linux x86_64.
- Quartus® Prime Software Version—including build number and installed interim updates. Click Help > About to obtain this information.
- Operating System—Windows or Linux operating system, excluding version updates. For example, Windows XP, Windows Vista, and Windows 7 results are identical. Similarly, Linux RHEL, CentOS 4, and CentOS 5 results are identical.