Visible to Intel only — GUID: dyy1518565098814
Ixiasoft
1.1. Compilation Overview
1.2. Using the Node Finder
1.3. Design Analysis & Elaboration
1.4. Design Synthesis
1.5. Design Place and Route
1.6. Incremental Optimization Flow
1.7. Fast Forward Compilation Flow
1.8. Full Compilation Flow
1.9. HSSI Dual Simplex IP Generation Flow
1.10. Exporting Compilation Results
1.11. Integrating Other EDA Tools
1.12. Compiler Optimization Techniques
1.13. Compilation Monitoring Mode
1.14. Synthesis Language Support
1.15. Synthesis Settings Reference
1.16. Fitter Settings Reference
1.17. Design Compilation Revision History
1.4.3.1. Registering the SDC-on-RTL SDC File
1.4.3.2. Applying the SDC-on-RTL Constraints
1.4.3.3. Inspecting SDC-on-RTL Constraints
1.4.3.4. Creating Constraints in SDC-on-RTL SDC Files
1.4.3.5. Using Entity-Based SDC-on-RTL Constraints
1.4.3.6. Types of SDC Files Used in the Quartus® Prime Software
1.4.3.7. Example: Using SDC-on-RTL Features
1.10.1. Exporting a Version-Compatible Compilation Database
1.10.2. Importing a Version-Compatible Compilation Database
1.10.3. Creating a Design Partition
1.10.4. Exporting a Design Partition
1.10.5. Reusing a Design Partition
1.10.6. Viewing Quartus Database File Information
1.10.7. Clearing Compilation Results
1.12.1. Compiler Optimization Modes
1.12.2. Precompiled Component (PCC) Generation Stage
1.12.3. Compilation on a Compute Farm
1.12.4. Allow Register Retiming
1.12.5. Automatic Gated Clock Conversion
1.12.6. Enable Intermediate Fitter Snapshots
1.12.7. Fast Preserve Option
1.12.8. Fractal Synthesis Optimization
2.1. Factors Affecting Compilation Results
2.2. Strategies to Reduce the Overall Compilation Time
2.3. Reducing Synthesis Time and Synthesis Netlist Optimization Time
2.4. Reducing Placement Time
2.5. Reducing Routing Time
2.6. Reducing Static Timing Analysis Time
2.7. Setting Process Priority
2.8. Reducing Compilation Time Revision History
Visible to Intel only — GUID: dyy1518565098814
Ixiasoft
1.6.1. Concurrent Analysis During Synthesis or Fitting
If you run Analysis & Synthesis, or the Fitter, you can access results while downstream Fitter stages are still running. Once the Concurrent Analysis icons become active in the dashboard, you can view the analysis without interrupting compilation.
During Analysis & Synthesis, you can click the Concurrent Analysis icons on the Dashboard to view reports, the RTL Viewer, or the Technology Map Viewer. While the Fitter is processing, you can analyze timing during the stages displaying the Timing Analyzer icon, and view Technology Map Viewer snapshots during Fitter stages.
CAUTION:
Do not attempt to change the SDC-on-RTL constraints during concurrent analysis. SDC-on-RTL constraints are read and loaded in the post-elaboration stage. If you modify the constraints at the Fitter stages, you must restart the compilation from the beginning.
Figure 80. Concurrent Analysis Options