11.4.10.4. TPIU

Figure 31. Trace Clock and Trace Data Width
Table 77.   TPIU SignalsThe following table lists the signal descriptions between the TPIU and FPGA.
Signal Description
h2f_tpiu_clk_ctl

Selects whether trace data is captured using the internal TPIU clock, which is the dbg_trace_clk signal from the clock manager; or an external clock provided as an input to the TPIU from the FPGA.

0 - use h2f_tpiu_clock_in

1 - use internal clock

Note: When the FPGA is powered down or not configured the TPIU uses the internal clock.

h2f_tpiu_data[32]

32 bit trace data bus to the FPGA. Trace data changes on both edges of h2f_tpiu_clock.

Note: When the FPGA is powered down or not configured, the TPIU sends the lower 8-bits trace data to I/Os.

h2f_tpiu_clock_in Clock from the FPGA used to capture trace data.
h2f_tpiu_clock Clock output from TPIU