Intel® Fortran Compiler Classic and Intel® Fortran Compiler Developer Guide and Reference

ID 767251
Date 11/07/2023
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

SPORT_SET_STATE_EX

Serial Port I/O Function: Sets the baud rate, parity, data bits setting, stop bits, and other settings of the communications port. This routine is only available for Windows.

Module

USE IFPORT

result = SPORT_SET_STATE_EX (port [,baud] [,parity] [,dbits] [,sbits] [,Binmode] [,DTRcntrl]

   [,RTScntrl] [,OutCTSFlow] [,OutDSRFlow] [,DSRSense] [,OutXonOff] [,InXonOff] [,XonLim]

   [,XoffLim] [,TXContOnXoff] [,ErrAbort] [,ErrCharEnbl] [,NullStrip] [,XonChar] [,XoffChar]

   [,ErrChar] [,EofChar] [,EvtChar] [,fZeroDCB])

port

(Input) Integer. The port number.

baud

(Input; optional) Integer. The baud rate of the port.

parity

(Input; optional) Integer. The parity setting of the port (0-4 = no, odd, even, mark, space).

dbits

(Input; optional) Integer. The data bits for the port.

sbits

(Input; optional) Integer. The stop bits for the port (0, 1, 2 = 1, 1.5, 2).

Binmode

(Input; optional) Integer. 1 if binary mode should be enabled; otherwise, 0. Currently, if this parameter is used, the value must be 1.

DTRcntrl

(Input; optional) Integer. 1 if DTR (data-terminal-ready) flow control should be used; otherwise, 0.

RTScntrl

(Input; optional) Integer. 1 if RTS (request-to-send) flow control should be used; otherwise, 0.

OutCTSFlow

(Input; optional) Integer. 1 if the CTS (clear-to-send) signal should be monitored for output flow control; otherwise, 0.

OutDSRFlow

(Input; optional) Integer. 1 if the DSR (data-set-ready) signal should be monitored for output flow control; otherwise, 0.

DSRSense

(Input; optional) Integer. 1 if the communications driver should be sensitive to the state of the DSR signal; otherwise, 0.

OutXonOff

(Input; optional) Integer. 1 if XON/XOFF flow control should be used during transmission; otherwise, 0.

InXonOff

(Input; optional) Integer. 1 if XON/XOFF flow control should be used during reception; otherwise, 0.

XonLim

(Input; optional) Integer. The minimum number of bytes that should be accepted in the input buffer before the XON character is set.

XoffLim

(Input; optional) Integer. The maximum number of bytes that should be accepted in the input buffer before the XOFF character is set.

TXContOnXoff

(Input; optional) Integer. 1 if transmission should be stopped when the input buffer is full and the driver has transmitted the XoffChar character; otherwise, 0.

ErrAbort

(Input; optional) Integer. 1 if read and write operations should be terminated when an error occurs; otherwise, 0.

ErrCharEnbl

(Input; optional) Integer. 1 if bytes received with parity errors should be replaced with the ErrChar character; otherwise, 0.

NullStrip

(Input; optional) Integer. 1 if null bytes should be discarded; otherwise, 0.

XonChar

(Input; optional) Character. The value of the XON character that should be used for both transmission and reception.

XoffChar

(Input; optional) Character. The value of the XOFF character that should be used for both transmission and reception.

ErrChar

(Input; optional) Character. The value of the character that should be used to replace bytes received with parity errors.

EofChar

(Input; optional) Character. The value of the character that should be used to signal the end of data.

EvtChar

(Input; optional) Character. The value of the character that should be used to signal an event.

fZeroDCB

(Input; optional) Integer. 1 if all settings of the communications port should be set to zero before parameters are set; otherwise, 0.

Results

The result type is INTEGER(4). The result is zero if successful; otherwise, a Windows* error value.

The following restrictions apply:

  • The number of data bits must be 5 to 8 bits.

  • The use of 5 data bits with 2 stop bits is an invalid combination, as is 6, 7, or 8 data bits with 1.5 stop bits.

NOTE:

This routine must not be used when any I/O is pending. Since a read operation is always pending after any I/O has been started, you must first call SPORT_CANCEL_IO before port parameters can be changed.

Example

USE IFPORT
INTEGER(4) iresult
iresult =  SPORT_SET_STATE_EX( 2, 9600, 0, 7, 1, OutXonOff=1, InXonOff=1,    &
              XonLim=1024, XoffLim=512, XonChar=CHAR(17), XoffChar=CHAR(19), &
              fZeroDCB=1) )
END

See Also