Visible to Intel only — GUID: esc1458237792275
Ixiasoft
1.1. Failure Rates
1.2. Mitigating SEU Effects in Embedded User RAM
1.3. Mitigating SEU Effects in Configuration RAM
1.4. Internal Scrubbing
1.5. SEU Recovery
1.6. Intel® Quartus® Prime Software SEU FIT Reports
1.7. Triple-Module Redundancy
1.8. Evaluating a System's Response to Functional Upsets
1.9. CRAM Error Detection Settings Reference
1.10. Document Revision History
Visible to Intel only — GUID: esc1458237792275
Ixiasoft
1.6.3. Enabling the Projected SEU FIT by Component Usage Report
The Intel® Quartus® Prime Fitter generates the Projected SEU FIT by Component Usage report. The Intel® Quartus® Prime software only generates reports for designs that successfully pass place and route.
To enable the report:
- Obtain and install the SEU license.
- Add the following assignments to your project's .qsf file:
set_global_assignment –name ENABLE_ADV_SEU_DETECTION ON set_global_assignment –name SEU_FIT_REPORT ON