AN 845: Signal Tap Tutorial for Intel® Arria® 10 Partial Reconfiguration Design
Visible to Intel only — GUID: lim1522173811274
Ixiasoft
Visible to Intel only — GUID: lim1522173811274
Ixiasoft
2.4.3. Setting Trigger Conditions
Direct the Signal Tap Logic Analyzer to record data only after u_blinking_led|led_three_on or u_blinking_led|led_two_on does a rising edge transition:
To set trigger conditions for the current revision:
- In the Setup tab of the Signal Tap Logic Analyzer window, turn on the box under the Trigger Condition column
- Open the drop-down menu and select Basic OR.
- For u_blinking_led|led_three_on and u_blinking_led|led_two_on, turn on Trigger Enable and select Rising Edge as the trigger type.
- For all the other signals, turn off Trigger Enable.
Defining trigger conditions completes the Signal Tap instance configuration.
Save your changes before you continue to compiling the design.