Visible to Intel only — GUID: fpz1575514346623
Ixiasoft
1.1. Introduction
1.2. Types of Intel® MAX® 10 Design Update Flow
1.3. Stages of Intel® MAX® 10 Hitless Update Flow
1.4. Intel® MAX® 10 Hitless Update Requirement and Limitation
1.5. Hitless Update using Intel® Quartus® Prime Programmer
1.6. Hitless Update using Intel® Jam STAPL Byte-Code Player
1.7. Hitless Update Using Self-Developed Algorithm
1.8. Boundary-Scan Pattern Configuration Bit Location
1.9. JTAG Instructions
1.10. Sample of Hitless Update Algorithm in Jam Format
1.11. Document Revision History for AN 904: Intel® MAX® 10 Hitless Update Implementation Guidelines
Visible to Intel only — GUID: fpz1575514346623
Ixiasoft
1.5.2. Executing IPS File
To execute ISP Clamp, perform the following steps:
- In the Intel® Quartus® Prime Programmer, select the .pof necessary to program to the device.
- Select the .pof, right click and select Add IPS File and turn-on ISP CLAMP.
Note: You can change the start-up delay of the I/O Clamp after configuration. To do this, select Tools > Options, turn on the Overwrite MAX10 configuration start up delay when using IO Clamp in Programmer option, and change the delay value accordingly.
- Select the .pof in the Program/Configure column.
Note: For third party programming, you can generate the .jam or .jbc file from the .pof file with .ips file.
- After you configure the required settings, click Start to start programming.