Visible to Intel only — GUID: odo1658328370527
Ixiasoft
1.2.1. Automatic Lane Polarity Inversion for PCIe Hard IP
1.2.2. Link Equalization Request Bit in the PCIe Hard IP Cannot Be Cleared by Software
1.2.3. High VCCBAT Current when VCC is Powered Down
1.2.4. Failure on Row Y59 When Using the Error Detection Cyclic Redundancy Check (EDCRC) or Partial Reconfiguration (PR)
1.2.5. GPIO Output may not meet the On-Chip Series Termination (Rs OCT) without Calibration Resistance Tolerance Specification or Current Strength Expectation
Description
Workaround
Status
Visible to Intel only — GUID: odo1658328370527
Ixiasoft
1.2.5. GPIO Output may not meet the On-Chip Series Termination (Rs OCT) without Calibration Resistance Tolerance Specification or Current Strength Expectation
Description
The GPIO pull-up impedance may not meet the on-chip series termination (Rs OCT) without calibration resistance tolerance specification mentioned in the Intel® Arria® 10 device datasheet. While using the current strength selection, the GPIO output buffer may not meet expected current strength at VOH voltage level when driving HIGH.
Workaround
Enable the on-chip series termination (Rs OCT) with calibration in your design.
Status
Affects:
- Intel® Arria® 10 GX 160 devices
- Intel® Arria® 10 GX 220 devices
- Intel® Arria® 10 GX 270 devices
- Intel® Arria® 10 GX 320 devices
- Intel® Arria® 10 GX 480 devices
- Intel® Arria® 10 GX 570 devices
- Intel® Arria® 10 GX 660 devices
Status: No planned fix.