The transmit DMA engine in default mode proceeds as follows:
  1. The Host sets up the transmit descriptor (TDES0‑TDES3) and sets the Own bit (TDES0[31]) after setting up the corresponding data buffer(s) with Ethernet frame data. 
  2. When Bit 13 (ST) of Register 6 (Operation Mode Register) is set, the DMA enters the Run state. 
  3. While in the Run state, the DMA polls the transmit descriptor list for frames requiring transmission. After polling starts, it continues in either sequential descriptor ring order or chained order. If the DMA detects a descriptor flagged as owned by the Host (TDES0[31] = 0), or if an error condition occurs, transmission is suspended and both the Bit 2 (Transmit Buffer Unavailable) and Bit 16 (Normal Interrupt Summary) of the Register 5 (Status Register) are set. The transmit Engine proceeds to 9.
  4. If the acquired descriptor is flagged as owned by DMA (TDES0[31] = 1), the DMA decodes the transmit Data Buffer address from the acquired descriptor.
  5. The DMA fetches the transmit data from the Host memory and transfers the data to the MTL for transmission. 
  6. If an Ethernet frame is stored over data buffers in multiple descriptors, the DMA closes the intermediate descriptor and fetches the next descriptor. Repeat 3, 4, and 5 until the end-of‑Ethernet‑frame data is transferred to the MTL. 
  7. When frame transmission is complete, if IEEE 1588 timestamping was enabled for the frame (as indicated in the transmit status) the timestamp value obtained from MTL is written to the transmit descriptor (TDES2 and TDES3) that contains the end‑of‑frame buffer. The status information is then written to this transmit descriptor (TDES0). Because the Own bit is cleared during this step, the Host now owns this descriptor. If timestamping was not enabled for this frame, the DMA does not alter the contents of TDES2 and TDES3. 
  8. Bit 0 (Transmit Interrupt) of Register 5 (Status Register) is set after completing transmission of a frame that has Interrupt on Completion (TDES1[31]) set in its Last descriptor. The DMA engine then returns to 3
  9. In the Suspend state, the DMA tries to re‑acquire the descriptor (and thereby return to 3) when it receives a Transmit Poll demand and the Underflow Interrupt Status bit is cleared. 