16.5.1. Software and Hardware Restrictions†

Only one data transfer command should be issued at one time. For CE-ATA devices, if CE-ATA device interrupts are enabled (nIEN=0), only one RW_MULTIPLE_BLOCK command (RW_BLK) should be issued; no other commands (including a new RW_BLK) should be issued before the Data Transfer Over status is set for the outstanding RW_BLK.

Before issuing a new data transfer command, the software should ensure that the card is not busy due to any previous data transfer command. Before changing the card clock frequency, the software must ensure that there are no data or command transfers in progress.

If the card is enumerated in SDR12 or SDR25 mode, the application must program the use_hold_reg bit[29] in the CMD register to 1’b1.

This programming should be done for all data transfer commands and non-data commands that are sent to the card. When the use_hold_reg bit is programmed to 1’b0, the SD/MMC controller bypasses the Hold Registers in the transmit path. The value of this bit should not be changed when a Command or Data Transfer is in progress.

For more information on using the use_hold_reg and the implementation requirements for meeting the card input hold time, refer to the latest version of the Synopsys® DesignWare® Cores Mobile Storage Host Databook.