15.5.2.6.1. Pipeline Read-Ahead Function
The pipeline read‑ahead function allows for a continuous reading of the flash memory. On receiving a pipeline read command, the flash controller immediately issues a load command to the device. While data is read out with MAP01 commands in a consecutive or multi‑plane address pattern, the flash controller maintains additional cache or multi‑plane read command sequencing for continuous streaming of data from the flash device.
Pipeline read‑ahead commands can read data from the queue in this interleaved fashion. The parameter <PP> denotes the total number of pages in multiples of the number of planes available, and the block address must be plane‑aligned, which keeps the page address constant while incrementing the block address for each page‑size chunk of data. After reading from every plane, the NAND flash controller increments the page address and resets the block address to the initial address. You can also use pipeline write‑ahead commands in multi‑plane mode. The write operation works similarly to the read operation, holding the page address constant while incrementing the block address until all planes are written.
Because the value of the flag bit of the multiplane_operation register in the config group determines pipeline read‑ahead or write‑ahead behavior, it can only be changed when the pipeline registers are empty.
When the host issues a pipeline read‑ahead command, and the flash controller is idle, the load operation occurs immediately.