Arria® V Device Handbook: Volume 1: Device Interfaces and Integration

ID 683213
Date 10/18/2023
Public
Document Table of Contents

11.8.1. Power Supplies Monitored and Not Monitored by the POR Circuitry

Table 122.  Power Supplies Monitored and Not Monitored by the Arria V POR Circuitry
Devices Power Supplies Monitored Power Supplies Not Monitored
Arria® V GX and GT
  • VCC_AUX
  • VCCBAT
  • VCC
  • VCCP
  • VCCPD
  • VCCPGM
  • VCCT_GXB
  • VCCH_GXB
  • VCCR_GXB
  • VCCA_GXB
  • VCCL_GXB
  • VCCA_FPLL
  • VCCD_FPLL
  • VCCIO
Arria® V GZ
  • VCC_AUX
  • VCCBAT
  • VCC
  • VCCPT
  • VCCPD
  • VCCPGM
  • VCCT_GXB
  • VCCH_GXB
  • VCCR_GXB
  • VCCA_GXB
  • VCCA_FPLL
  • VCCD_FPLL
  • VCCIO
  • VCCHIP
Arria® V SX and ST
  • VCC_AUX
  • VCCBAT
  • VCC
  • VCCP
  • VCCPD
  • VCCPGM
  • VCC_HPS
  • VCCPD_HPS
  • VCCRSTCLK_HPS
  • VCC_AUX_SHARED
  • VCCT_GXB
  • VCCH_GXB
  • VCCR_GXB
  • VCCA_GXB
  • VCCL_GXB
  • VCCA_FPLL
  • VCCD_FPLL
  • VCCIO
  • VCCIO_HPS
  • VCCPLL_HPS
Note: For the device to exit POR, you must power the VCCBAT power supply even if you do not use the volatile key.