Arria® V Device Handbook: Volume 1: Device Interfaces and Integration

ID 683213
Date 10/18/2023
Public
Document Table of Contents

11.1.1. Dynamic Power Equation

Figure 224. Dynamic PowerThe following equation shows how to calculate dynamic power where P is power, C is the load capacitance, and V is the supply voltage level.


The equation shows that power is design-dependent and is determined by the operating frequency of your design. Arria® V devices minimize static and dynamic power using advanced process optimizations. This technology allows Arria® V designs to meet specific performance requirements with the lowest possible power.