Visible to Intel only — GUID: hnb1573151014136
Ixiasoft
1. About this Document
2. System Requirements
3. Hardware Installation
4. Installing the OPAE Software
5. OPAE Tools
6. Sample Test: Native Loopback
7. Installing the Intel XL710 Driver
8. Configuring Ethernet Interfaces
9. Testing Network Loopback Using Data Plane Development Kit (DPDK)
10. Graceful Shutdown
11. Single Event Upset (SEU)
12. Document Revision History for Intel Acceleration Stack User Guide: Intel® FPGA PAC N3000
A. Troubleshooting
B. Upgrade your Intel® FPGA PAC N3000 with Production Version of BMC and Intel® Arria® 10 Image
C. Configure the 4.19 Kernel
D. fpgabist Sample Output
Visible to Intel only — GUID: hnb1573151014136
Ixiasoft
4.3. Identify the Intel® MAX® 10 Version on your Intel® FPGA PAC N3000
Run the following command and verify the output with the table below:
If your Intel® FPGA PAC N3000 does not have the production version of Intel® MAX® 10 NIOS Firmware (FW) and Build, refer to the section: Upgrade your Intel FPGA PAC N3000 with Production Version of BMC and Intel Arria 10 Image. When you upgrade your Intel® FPGA PAC N3000 from Alpha-2/Beta version to Production version, refer to the following table for Bitstream ID and PR Interface ID:
$sudo fpgainfo fme
Acceleration Stack 1.1 for Intel® FPGA PAC N3000 | Intel® MAX® 10 NIOS Firmware (FW) | Intel® MAX® 10 Build |
---|---|---|
Production | D.2.0.19 | D.2.0.6 |
Beta | D.2.0.12 | D.2.0.5 |
Alpha-2 | D.1.0.13 | D.1.0.14 |
Alpha-1 | D.1.0.13 | D.1.0.13 |
Intel® FPGA PAC N3000 | Factory Partition Image | User Partition Image | ||||
---|---|---|---|---|---|---|
Configuration | Bitstream ID | PR Interface ID | Configuration | Bitstream ID | PR Interface ID | |
BD-NVV-N3000-2 | 2x2x25G | 0x23000410010309 | a5d72a3c-c8b0-4939-912c-f715e5dc10ca | 4x25G | 0x23000110010309 | f3c99413-5081-4aad-bced-07eb84a6d0bb |
BD-NFV-N3000-1 | 8x10G | 0x23000010010309 | 901dd697-ca79-4b05-b843-8138cefa2846 | 8x10G | 0x23000010010309 | 901dd697-ca79-4b05-b843-8138cefa2846 |
If your Intel® FPGA PAC N3000 has the production version of Intel® MAX® 10 Firmware and Build, install the PV 1.1 Patch. When your Intel® FPGA PAC N3000 is shipped with the production version, refer to the following table for Bitstream ID and PR Interface ID:
Intel® FPGA PAC N3000 | Factory Partition Image | User Partition Image | ||||
---|---|---|---|---|---|---|
Configuration | Bitstream ID | PR Interface ID | Configuration | Bitstream ID | PR Interface ID | |
BD-NVV-N3000-2 | 2x2x25G | 0x2300041001030F | a5d72a3c-c8b0-4939-912c-f715e5dc10ca | 4x25G | 0x2300011001030F | f3c99413-5081-4aad-bced-07eb84a6d0bb |
BD-NFV-N3000-1 | 8x10G | 0x2300001001030F | 901dd697-ca79-4b05-b843-8138cefa2846 | 8x10G | 0x2300001001030F | 901dd697-ca79-4b05-b843-8138cefa2846 |