Visible to Intel only — GUID: hno1573159912655
Ixiasoft
1. About this Document
2. System Requirements
3. Hardware Installation
4. Installing the OPAE Software
5. OPAE Tools
6. Sample Test: Native Loopback
7. Installing the Intel XL710 Driver
8. Configuring Ethernet Interfaces
9. Testing Network Loopback Using Data Plane Development Kit (DPDK)
10. Graceful Shutdown
11. Single Event Upset (SEU)
12. Document Revision History for Intel Acceleration Stack User Guide: Intel® FPGA PAC N3000
A. Troubleshooting
B. Upgrade your Intel® FPGA PAC N3000 with Production Version of BMC and Intel® Arria® 10 Image
C. Configure the 4.19 Kernel
D. fpgabist Sample Output
Visible to Intel only — GUID: hno1573159912655
Ixiasoft
B.1.2. Root Entry Hash Not Programmed
- Rollback the Intel® MAX® 10 and Intel® Arria® 10 image to allow update:
$ sudo super-rsu /usr/share/opae/n3000/one-time-update/<25G or 10G>/\ rollback-*.json --with-rsu
$ sudo fpgainfo fme
Note: The Intel® MAX® 10 build version will be 111.2.13 after performing rollback.
This sysfs entry must exist.$ ls -l /sys/class/fpga/intel-fpga-dev.*/intel-fpga-fme.*/\ spi-altera.*.auto/spi_master/spi*/spi*/intel-generic-qspi.*.auto/
- Run the One-Time Secure Update (OTSU):
$ sudo fpgaotsu /usr/share/opae/n3000/one-time-update/*/otsu-*.json --rsu
If OTSU fails, run the fpgainfo fme to find out the Intel® MAX® 10 build version and take appropriate action as stated:Intel® MAX® 10 Build Version Action D.111.2.13 Repeat OTSU D.2.0.6 Run command: sudo super-rsu /usr/share/opae/n3000/super-rsu/<2x2x25G, 4x25G or 8x10G>/super-rsu-*.json --with-rsu
- To verify successful OTSU:
sudo fpgaotsu /usr/share/opae/n3000/one-time-update/<25G or 10G>/\ otsu-*.json --verify
At this point, the Intel® FPGA PAC N3000 will have the following Intel® Arria® 10 image, Intel® MAX® 10 NIOS FW and Intel® MAX® 10 Build versions.Configuration User Partition Image Bitstream ID PR interface ID Intel® MAX® 10 NIOS FW Intel® MAX® 10 BUILD 2x2x25G 4x25G 0x2300110010309 f3c99413-5081-4aad-bced-07eb84a6d0bb D.2.0.19 D.2.0.6 4x25G 8x10G 8x10G 0x2300010010309 901dd697-ca79-4b05-b843-8138cefa2846 D.2.0.19 D.2.0.6 Important: The 2x2x25G or 4x25G Configuration Installer loads the FPGA flash user partition with 4x25G Intel provided factory test image and loads factory partition with 2x2x25G Intel provided factory test image. The 8x10 Configuration Installer loads both the user and factory FPGA flash partitions with 8x10G Intel provided factory test image. - Install the PV 1.1 Patch.