8.2.6. Running BER Tests

After you create the transceiver links for debugging, you can run BER tests from the Channel Parameters tab:

  1. In the Collection status table, select the pin for the TX and RX channels you want to test.
  2. In the Channel Parameters tab, select the PRBS pattern in the TX and RX channels.
  3. Set the TX Equalization Parameters. Key in the values, click Set Parameters. To load the values, click Get Parameters.
  4. Click Start in the TX Channel to start the Hard PRBS generator.
  5. Click TX Reset UX PMA and RX Reset UX PMA. This step is only applicable to FGT.
  6. Click Start in the RX Channel to start the Hard PRBS checker.
  7. To stop the test, click Stop in the RX Channel and TX Channel.
  8. If you want to run another BER test with a different PRBS pattern or TX equalization parameters, repeat steps 2 to 7.
The following figure shows the setup and results for an example BER test for the FGT PMA.
Figure 122. Example BER Test Setup and Results for the FGT PMA