Document Version Intel® Quartus® Prime Version Changes
2024.02.09 23.4
  • Updated the document to clarify that the programmable pull-up resistor and programmable bus-hold features are supported only for input and bidirectional pins.
  • Updated the I/O pins placement requirements topic to clarify that you cannot split the clock enable in and clock enable out signals.
2023.10.31 23.3 Added package R2340A with F-Tile ×1.
2023.07.04 23.2 Updated the guidelines about VREF sources and VREF pins to clarify that the guidelines apply only to inputs.
2023.04.19 23.1 Added package R3184B to the AGI 041 device.
2023.02.20 22.4
  • Added the AGI 041 device.
  • Added package R3184A.
  • Updated product family name to "Intel® Agilex™ 7".
  • Retitled the document from Intel® Agilex™ F-Series and I-Series General-Purpose I/O User Guide to Intel® Agilex™ 7 General-Purpose I/O User Guide: F-Series and I-Series.
2022.09.29 22.3
  • In the table listing the selectable I/O standards for RS OCT for GPIO banks, removed the RS OCT with calibration values for the 1.2 V LVCMOS I/O standard.
  • In the guideline for VREF sources and VREF pins, clarified that the internal VREF is supported only for external memory interfaces.
2022.06.14 22.1 Removed package R3184A.
2022.03.28 22.1
  • Restructured and rewritten the document to improve ease of reference and modularity.
  • Retitled the document from Intel® Agilex™ General-Purpose I/O and LVDS SERDES User Guide to Intel® Agilex™ F-Series and I-Series General-Purpose I/O User Guide.
  • Moved the LVDS SERDES sections to a new document: Intel® Agilex™ F-Series and I-Series LVDS SERDES User Guide.
  • Updated the vertical migration support figure:
    • Added Intel® Agilex™ AGI 035 and AGI 040 product lines
    • Changed packages F2581A to R2581A and R1935A to R1805A
  • Updated the slew rate control settings for the SSTL-12 I/O standard in the topic listing the programmable I/O element features for the GPIO bank.
  • Removed "Programmable open-drain output" from the list of Assignment Editor features. You can turn on the open drain feature through the GPIO Intel® FPGA IP parameter editor.
  • Added topics about IBIS models.
  • In the topic about VREF sources and VREF pins, clarified that you cannot mix the POD12 I/O standard with other voltage-referenced I/O standards in the same I/O lane.
  • Corrected the output clock name in the topic about the single data rate output register from sdr_out_clk to sdr_out_outclk.
  • Updated the figure showing the examples of True Differential Signaling receiver pairs placement to improve clarity.
  • Updated the supported slew rate values in the topic listing the HPS I/O programmable IOE features assignment names and settings.
  • Removed the user guide archives section. For the latest and previous versions of this user guide, refer to the Intel® Agilex™ F-Series and I-Series General-Purpose I/O User Guide.
2021.10.29 21.3
  • Updated the topic about the I/O buffer behavior to add more details on the power up, power down, and turned off conditions.
  • Updated the guidelines for I/O pins in GPIO, HPS, and SDM banks during power sequencing.
  • Added a section listing the I/O standards and features for configuration pins in different configuration schemes.
  • Removed the table listing the configuration pin I/O standards and features.
2021.10.04 21.3
  • Updated the package selection and I/O vertical migration information.
  • Updated the topic about programmable de-emphasis:
    • The de-emphasis effect now affects signals at 1 UI or 0.5 UI depending on the interface clock frequency.
    • Restructured the content for easier reference.
  • Updated the GPIO IP version to 21.0.0.
  • Removed NCSim support.
2021.07.15 21.2 Updated the diagram that shows the simplified view of the single-ended GPIO input path to update dout[0] to dout[3] and dout[3] to dout[0].
2021.04.05 21.1
  • Updated the vertical migration table:
    • Removed the AGF 004 product line.
    • Removed the F1149A, R1615A, R2013A, R2470A, R3179C, R2581A, R3179B, and R3179A packages.
    • Added R1546A, R2340A, R3184C, F2581A, R3184B, and R3184A packages.
  • Removed H-Tile and 3 V I/O support.
  • Removed the Intel® Agilex™ AGF 014 FPGA.
  • Updated default settings for the POD-12 and Differential POD-12 I/O standards from "High" to "Off".
  • Added a topic about the Schmitt Trigger input buffer feature.
  • Added assignment settings for the Schmitt Trigger input buffer.
  • Added support for assigning 0 V, 1.2 V, or 1.5 V to the VCCIO_PIO pin in unused I/O banks.
  • Updated the figures showing the I/O bank structure to improve clarity and to remove 3 V I/O.
  • Updated the IP version for the GPIO and LVDS SERDES IPs to 20.0.0.
2020.09.28 20.3
  • Added 3 V H-Tile I/O information in the following topics:
    • General-purpose I/O and LVDS SERDES Overview.
    • Intel® Agilex™ I/O and Differential I/O Buffers.
    • I/O Banks.
    • Supported I/O Standards.
    • Programmable I/O Element (IOE) Features in Intel® Agilex™ Devices.
    • Single-Ended I/O Standard OCT Termination.
    • RS OCT.
    • Single-ended I/O Standards External Termination.
    • Input Path.
    • GPIO Intel FPGA IP Architecture.
  • Updated the voltage level of a pin signal during power down in the I/O Buffer Behavior.
  • Updated the Supported Usage Modes with Number of IP Instances in an I/O Sub-bank table to clarified the maximum number of transmitter and receiver channels per IP instance.
  • Updated lvds_clk and ext_lvds_clk signals width in the following tables:
    • Example: Generating Output Clocks Using an IOPLL IP (Receiver in Non-DPA Mode).
    • Example: Generating Output Clocks Using an IOPLL IP (Receiver in DPA or Soft-CDR Mode).
    • Example: Generating Output Clocks Using a Shared IOPLL IP for Transmitter and Receiver Channels (Receiver in DPA or Soft-CDR Mode).
  • Removed information about transmitter spanning across multiple I/O banks feature in the following topics:
    • IOPLL Parameter Values for External PLL Mode.
    • Intel® Agilex™ LVDS Interface with External PLL Mode.
  • Updated the IOPLL IP settings in the Signal Interface between IOPLL and LVDS SERDES IPs table.
  • Updated the Soft-CDR LVDS Receiver Interface with the IOPLL IP (with LVDS transmitter in the same sub-bank) figure.
  • Added the following guideline topics in the I/O Design Guidelines chapter:
    • Voltage Setting for Unused I/O Banks.
    • Drive Strength Requirement for GPIO Input Pins.
    • Observe Device Absolute Maximum Rating for 3.0 V Interfacing.
    • Use Only One Voltage for All 3 V I/O Banks.
    • Maximum True Differential Signaling RX Pairs Per I/O Lane.
    • Do Not Drive 3 V I/O Pins During Power Sequencing.
  • Updated LVDS SERDES Intel FPGA IP version to 19.5.0 with the following change:
    • Improved the power usage of the IP.
    • Removed the Duplex Feature parameter in the General Settings Tab table.
    • Updated the condition for FPGA/PLL speed grade in the PLL Settings Tab table.
  • Added short descriptions for General-purpose I/O Debug Guidelines and High-speed SERDES I/O Debug Guidelines tables.
2020.06.22 20.2
  • Changed R2560A name to R2581A in the Migration Capability Across Intel® Agilex™ Product Lines—Preliminary image.
  • Clarified that programmable de-emphasis feature is only available when using Fast slew rate setting in the Programmable IOE Feature Settings for Intel® Agilex™ GPIO Bank table and Programmable De-Emphasis section.
  • Added new GPIO Pins for Avalon-ST Configuration Scheme guideline topic.
  • Added the Troubleshooting Guidelines topic.
  • Added the following KDB links to the Transmitter Channel-to-Channel Skew and Receiver Skew Margin topics:
    • Why does the “TCCS Report” in LVDS SERDES Intel® FPGA IP SDC report an invalid TCCS value?
    • Why does the “TCCS Report” in LVDS SERDES Intel® FPGA IP SDC report an invalid TCCS value?
  • Added the release notes links to the GPIO Intel FPGA IP Release Information, OCT Intel FPGA IP Release Information, and LVDS SERDES Intel FPGA IP Release Information topics.
2020.04.13 20.1
  • Updated the Programmable IOE Feature Settings for Intel® Agilex™ GPIO Bank table with default slew rate settings for GPIO and EMIF implementations.
  • Updated the Programmable Output Slew Rate Control topic to specify different slew rate settings per design implementation.
  • Removed recommendation to use HSPICE simulation to verify output voltages in th e Programmable Open-Drain Output topic.
  • Updated guidelines in the External I/O Termination topic.
  • Added the AC-Coupled External Termination for 1.2 V VCCIO_PIO figure in the External I/O Termination.
  • Added the Simulation Models Descriptions table in the I/O Simulation topic.
  • Updated OCT Intel FPGA IP and GPIO Intel FPGA IP connections for user mode calibration in the User Mode OCT topic.
  • Added RZQ_GROUP QSF assignment description in the QSF Assignments table.
  • Added OCT block and primitive I/O buffer connection figure in the QSF Assignments topic.
  • Renamed the Guidelines for GPIO Pins During Power Sequencing section to Guidelines for I/O Pins in GPIO, HPS, and SDM Banks During Power Sequencing and updated the guidelines for GPIO, HPS, and SDM I/O pins in the section.
  • Updated information about LVDS SERDES Intel FPGA IP version 19.4.0:
    • Updated pll_areset signal connections in Non-DPA or DPA LVDS Receiver Interface with the IP (with LVDS transmitter in the same sub-bank), Soft-CDR LVDS Receiver Interface with the IP (with LVDS transmitter in the same sub-bank), and LVDS Transmitter Interface with the IP figures.
    • Added description for ext_pll_locked signal in the External PLL Signals for LVDS SERDES IP and the Signal Interface between IOPLL and LVDS SERDES IPs tables.
    • Added a note about the delay between the ext_pll_locked signal and the pll_locked signal assertions in the Initializing the LVDS SERDES IP in DPA Mode and the Initializing the LVDS SERDES IP in Non-DPA Mode topics.
2019.12.16 19.4
  • Updated information for GPIO Intel FPGA IP version 19.3.0:
    • Changed seriesterminationcontrol and parallelterminationcontrol signals to terminationcontrol signal.
  • Updated description on calibration block for mix I/O standards in the OCT Calibration Block topic.
  • Added information about LVDS SERDES Intel FPGA IP version 19.3.0.
  • Added Example of x4 DQ Groups with Shared OE, Reset, and Clock Enable Signals in Pinout Files figure in the Placement Requirements topic.
  • Added Simultaneous Switching Noise and Clocking Requirements topics in the I/O Design Guidelines chapter.
  • Added Placing LVDS Transmitters and Receivers in the Same I/O Bank and Using an External PLL topics in the LVDS SERDES Design Guidelines chapter.
  • Added information to generate design example for OCT Intel FPGA IP version 19.3.0.
  • Added Net Length Reports topic.
2019.09.30 19.3
  • Changed differential signaling naming from 1.5 V True Differential Signaling to True Differential Signaling.
  • Added Input and Output columns for VCCIO_PIO voltage in the Intel® Agilex™ GPIO Bank Supported I/O Standards table.
  • Added Intel® Quartus® Prime assignment names for each I/O standards.
  • Added the following topics:
    • I/O Buffer and Registers in Intel® Agilex™ Devices
    • Configuring I/O Assignments in Intel® Quartus® Prime Software
    • Configuring I/O Assignments Using Assignment Editor
    • Configuring I/O Standards Using Pin Planner
    • Configuring OCT Using Assignment Editor
    • Configuring Differential Input RD OCT Using Assignment Editor
  • Restructured the Intel® Agilex™ I/O Termination chapter.
  • Updated default RS OCT calibration values in the Selectable I/O Standards for RS OCT table.
  • Added explanation on the number of RS and RT OCT settings can a OCT calibration block supports for all I/O standards in OCT Calibration Block topic.
  • Restructured the I/O and LVDS SERDES Design Guidelines chapter.
  • Added the following diagrams in the Programmable De-Emphasis section:
    • Signal Attenuation for De-emphasis Off for SSTL and HSTL I/O Standards
    • Signal Attenuation for Constant Impedance De-emphasis for SSTL and HSTL I/O Standards
    • Signal Attenuation for Low Power De-emphasis for SSTL and HSTL I/O Standards
    • Signal Attenuation for De-emphasis Off for POD12 I/O Standard
    • Signal Attenuation for Low Power De-emphasis for POD12 I/O Standard
  • Removed maximum DC current restrictions for Intel® Agilex™ devices in the Maximum DC Current Restrictions topic.
  • Added the OCT Calibration Block Requirement topic in Intel® Agilex™ I/O Design Guidelines.
  • Added new restrictions about using AVSTx16 or AVSTx32 configuration scheme in SDM Shared I/O Requirements topic.
  • Changed maximum VREF pin leakage current from 4 µA to 8 µA.
  • Added information about GPIO Intel FPGA IP version 19.3.0.
  • Added information about OCT Intel FPGA IP version 19.3.0.
2019.04.02 19.1 Initial release.