7.1. Configuration Debugging Checklist
Checklist Item | Complete? | ||
---|---|---|---|
1 | Verify that all configuration resistors are correctly connected (MSEL, nCONFIG, nSTATUS, CONF_DONE, INIT_DONE, PWRMGT_SDA, PWRMGT_SCL). | ☐ | |
2 | Verify that you are following the correct power-up and power-down sequences. | ☐ | |
3 | Verify that the SDM I/Os assignments are correct by checking the Intel® Quartus® Prime Compilation QSF and Fitter reports. | ☐ | |
4 | For SmartVID devices (-V or -E), ensure that all PMBus pins are connected to Intel® Agilex™ device. | ☐ | |
5 | Verify that SmartVID settings follow the recommendations in the Intel® Agilex™ Power Management User Guide | ☐ | |
6 | Verify that the Intel® Agilex™ -V or -E device has its own voltage regulator module for VCC, VCCP, VCCL_HPS, and VCCPLLDIG_HPS | ☐ | |
7 | After configuration are the nCONFIG, nSTATUS, CONF_DONE, and INIT_DONE pins high? For more information about configuration status, refer to the Understanding Configuration Status Using quartus_pgm Command section. |
☐ | |
8 | Is the SDM operating Boot ROM code or configuration firmware? |
☐ | |
9 | Are the MSEL pins correctly connected on board? | ☐ | |
10 | For designs that use transceivers, HBM2, PCIe* , or EMIF, are the reference clocks stable and free running before configuration begins? | ☐ | |
11 | Verify that selected clocks match the frequency setting specified in the Intel® Quartus® Prime software during configuration. | ☐ | |
12 | Does your design include the Reset Release IP? | ☐ | |
13 | To avoid configuration failures, disconnect the PMBus regulator’s JTAG download cable before configuring Intel® Agilex™ -V devices. | ☐ | |
14 | Verify that the Intel® Agilex™ device has exited POR by checking nCONFIG, nSTATUS, CONF_DONE and INIT_DONE pins using an oscilloscope. | ☐ | |
15 | Is the configuration clock source chosen appropriately? You can use an internal oscillator or the OSC_CLK_1 pin. | ☐ | |
16 | For designs driving the OSC_CLK_1 pin is the frequency 25, 100, or 125 MHz? | ☐ | |
17 | For Intel® Agilex™ SX parts ensure that the HPS and EMIF IOPLL reference clocks are stable and free running before configuration begins. The actual frequency should match the setting specified in Platform Designer. | ☐ | |
18 | Are proper slave addresses set for the PMBus voltage regulator modules using the Intel® Quartus® Prime Software? | ☐ | |
19 | For designs that use 3 V I/0, verify that the transceiver tiles are powered up before configuration begins. | ☐ |