Visible to Intel only — GUID: jbr1442879364995
Ixiasoft
3.1. Creating a New FPGA Design Project
3.2. Viewing Basic Project Information
3.3. Intel® Quartus® Prime Project Contents
3.4. Managing Project Settings
3.5. Managing Logic Design Files
3.6. Managing Timing Constraints
3.7. Integrating Other EDA Tools
3.8. Exporting Compilation Results
3.9. Migrating Projects Across Operating Systems
3.10. Archiving Projects
3.11. Command-Line Interface
3.12. Managing Projects Revision History
3.8.1. Exporting a Version-Compatible Compilation Database
3.8.2. Importing a Version-Compatible Compilation Database
3.8.3. Creating a Design Partition
3.8.4. Exporting a Design Partition
3.8.5. Reusing a Design Partition
3.8.6. Viewing Quartus Database File Information
3.8.7. Clearing Compilation Results
4.1. Design Planning
4.2. Create a Design Specification and Test Plan
4.3. Plan for the Target Device or Board
4.4. Plan for Intellectual Property Cores
4.5. Plan for Standard Interfaces
4.6. Plan for Device Programming
4.7. Plan for Device Power Consumption
4.8. Plan for Interface I/O Pins
4.9. Plan for other EDA Tools
4.10. Plan for On-Chip Debugging Tools
4.11. Plan HDL Coding Styles
4.12. Plan for Hierarchical and Team-Based Designs
4.13. Design Planning Revision History
5.1. IP Catalog and Parameter Editor
5.2. Installing and Licensing Intel® FPGA IP Cores
5.3. IP General Settings
5.4. Adding IP to IP Catalog
5.5. Best Practices for Intel® FPGA IP
5.6. Specifying the IP Core Parameters and Options ( Intel® Quartus® Prime Pro Edition)
5.7. IP Core Generation Output ( Intel® Quartus® Prime Pro Edition)
5.8. Scripting IP Core Generation
5.9. Modifying an IP Variation
5.10. Upgrading IP Cores
5.11. Simulating Intel® FPGA IP Cores
5.12. Generating Simulation Files for Platform Designer Systems and IP Variants
5.13. Synthesizing IP Cores in Other EDA Tools
5.14. Instantiating IP Cores in HDL
5.15. Support for the IEEE 1735 Encryption Standard
5.16. Introduction to Intel FPGA IP Cores Revision History
6.2.1. Modify Entity Name Assignments
6.2.2. Resolve Timing Constraint Entity Names
6.2.3. Verify Generated Node Name Assignments
6.2.4. Replace Logic Lock (Standard) Regions
6.2.5. Modify Signal Tap Logic Analyzer Files
6.2.6. Remove References to .qip Files
6.2.7. Remove Unsupported Feature Assignments
6.4.1. Verify Verilog Compilation Unit
6.4.2. Update Entity Auto-Discovery
6.4.3. Ensure Distinct VHDL Namespace for Each Library
6.4.4. Remove Unsupported Parameter Passing
6.4.5. Remove Unsized Constant from WYSIWYG Instantiation
6.4.6. Remove Non-Standard Pragmas
6.4.7. Declare Objects Before Initial Values
6.4.8. Confine SystemVerilog Features to SystemVerilog Files
6.4.9. Avoid Assignment Mixing in Always Blocks
6.4.10. Avoid Unconnected, Non-Existent Ports
6.4.11. Avoid Illegal Parameter Ranges
6.4.12. Update Verilog HDL and VHDL Type Mapping
Visible to Intel only — GUID: jbr1442879364995
Ixiasoft
6.2.7. Remove Unsupported Feature Assignments
The Intel® Quartus® Prime Pro Edition software does not support some feature assignments that other Quartus software products support. Remove the following unsupported feature assignments from other Quartus software product .qsf files for migration to the Intel® Quartus® Prime Pro Edition software.
- Incremental Compilation (partitions)—The current version of the Intel® Quartus® Prime Pro Edition software does not support Intel® Quartus® Prime Standard Edition incremental compilation. Remove all incremental compilation feature assignments from other Quartus software product .qsf files before migration.
- Intel® Quartus® Prime Standard Edition Physical synthesis assignments. Intel® Quartus® Prime Pro Edition software does not support Intel® Quartus® Prime Standard Edition Physical synthesis assignments. Remove any of the following assignments from the .qsf file or design RTL (instance assignments) before migration.
PHYSICAL_SYNTHESIS_COMBO_LOGIC_FOR_AREA PHYSICAL_SYNTHESIS_COMBO_LOGIC PHYSICAL_SYNTHESIS_REGISTER_DUPLICATION PHYSICAL_SYNTHESIS_REGISTER_RETIMING PHYSICAL_SYNTHESIS_ASYNCHRONOUS_SIGNAL_PIPELINING PHYSICAL_SYNTHESIS_MAP_LOGIC_TO_MEMORY_FOR_AREA
Note: If you open a Intel® Quartus® Prime Standard Edition software project in the Intel® Quartus® Prime Pro Edition software, and that project contains unsupported junction temperature setting values, you can modify these settings by clicking Assignments > Settings > Operating Settings and Conditions > Temperature. Click OK, and then click Yes when prompted to update the values.