2.3. Supported Command Sets

Supported MCTP Commands

  • Get MCTP Version Support
    • Base Spec Version Info
    • Control Protocol Version Info
    • PLDM over MCTP Version
  • Set Endpoint ID
  • Get Endpoint ID
  • Get Endpoint UUID
  • Get Message Type Support
  • Get Vendor Defined Message Support
Note: For Get Vendor Defined Message Support command, the BMC responds with the completion code ERROR_INVALID_DATA(0x02).

Supported PLDM Base Specification Commands

  • SetTID
  • GetTID
  • GetPLDMVersion
  • GetPLDMTypes
  • GetPLDMCommands

Supported PLDM for Platform Monitoring and Control Specification Commands

  • SetTID
  • GetTID
  • GetSensorReading
  • GetSensorThresholds
  • SetSensorThresholds
  • GetPDRRepositoryInfo
  • GetPDR
Note: The polling duration of the telemetry data by BMC NIOS is about 500~800 milliseconds (ms). Therefore, the duration between the start of the request message commands and getting the corresponding responses back is 500~800 ms. The interval between getting responses back from the previous command and the start of the next request message commands is 1 ms.
Note: GetStateSensorReadings is not supported.