2.3. Supported Command Sets
Supported MCTP Commands
- Get MCTP Version Support
- Base Spec Version Info
- Control Protocol Version Info
- PLDM over MCTP Version
- Set Endpoint ID
- Get Endpoint ID
- Get Endpoint UUID
- Get Message Type Support
- Get Vendor Defined Message Support
Note: For Get Vendor Defined Message Support command, the BMC responds with the completion code ERROR_INVALID_DATA(0x02).
Supported PLDM Base Specification Commands
- SetTID
- GetTID
- GetPLDMVersion
- GetPLDMTypes
- GetPLDMCommands
Supported PLDM for Platform Monitoring and Control Specification Commands
- SetTID
- GetTID
- GetSensorReading
- GetSensorThresholds
- SetSensorThresholds
- GetPDRRepositoryInfo
- GetPDR
Note: The polling duration of the telemetry data by BMC NIOS is about 500~800 milliseconds (ms). Therefore, the duration between the start of the request message commands and getting the corresponding responses back is 500~800 ms. The interval between getting responses back from the previous command and the start of the next request message commands is 1 ms.
Note: GetStateSensorReadings is not supported.