AN 802: Intel® Stratix® 10 SoC Device Design Guidelines

ID 683117
Date 12/14/2020
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

5.12.2. Using a Single flash for Both FPGA Configuration and HPS Mass Storage

The QSPI device connected to the SDM can also be accessed directly by the HPS. However, there is a significant speed penalty when doing so. It is up to you to decide whether the speed penalty is acceptable for the end application.

For reference, here are some performance numbers:

  • Maximum HPS eMMC read speed: 50Mbytes/s
  • Maximum HPS SD read speed: 25Mbytes/s
  • Maximum HPS read speed from SDM QSPI: 4Mbytes/s

GUIDELINE: For best performance, Intel® recommends to use a flash device connected to HPS for mass storage by HPS.