5.3.2. INFO
The fRSmartComp implements reset value or default register value as follows:
- In the absence of physical faults, the reset values are implemented after an asynchronous reset.
- In physical faults, the fRSmartComp maintains the fRNET Interface outputs classified as ALARMS, CONTEXT, and STATISTIC information after an asynchronous reset or DISABLE operation.
Therefore, the outputs of these types may not have the default register values after an asynchronous reset.
Assume that after you detect a fault and restart the CPU/fRSmartComp using a certain reset scenario, the values on fRNET Interface outputs are preserved. This ensures you can analyze the information related to the fault and failure control for subsequent actions, not those reset values.
Signal Names | Width (bits) | Direction | Description |
---|---|---|---|
FRNET_ENABLED_C | 2 | Output | Output that states if the fRSmartComp is enabled or not.
|
FRNET_MODEOUT | 24 | Output | fRSmartComp mode selector status output. Default value at 0x0FAA55 if SILENT mode is not active. |
FRNET_GI_ALARMS | 24 | Output | fRSmartComp alarms outputs. Default value is 0 (No ALARMS triggered). |
FRNET_GI_CTXT_0 | 24 | Output | Reserved |
FRNET_GI_CTXT_1 | 24 | Output | Reserved |
FRNET_GI_CTXT_2 | 24 | Output | Reserved |
FRNET_GI_CTXT_3 | 24 | Output | Reserved |
FRNET_GI_CTXT_4 | 24 | Output | Error Controller Context information (on self-detections) Default value is 0 (No events triggering ALARM19). |
FRNET_GI_CMP_CTXT_0 | 24 | Output | Comparator context information - which one or more slices gave mismatch at comparator error. The default value is 0. |
FRNET_GI_CMP_CTXT_1 | 24 | Output | Reserved |
FRNET_GI_CMP_CTXT_2 | 24 | Output | Reserved |
FRNET_GI_CMP_CTXT_3 | 24 | Output | Reserved |
FRNET_GI_STAT_0 | 24 | Output | DCLSM STATISTICS information:
Default value is 0. |
FRNET_GI_STAT_1 | 24 | Output | Reserved |
FRNET_GI_STAT_2 | 24 | Output | Reserved |
FRNET_GI_STAT_3 | 24 | Output | Reserved |
FRNET_GI_STAT_4 | 24 | Output | Error Controller statistic register:
Default value is 0. |
FRNET_PERIPH_GI_0 | 24 | Output | Reserved |
FRNET_PERIPH_GI_1 | 24 | Output | Reserved |
FRNET_PERIPH_GI_2 | 24 | Output | Reserved |
FRNET_PERIPH_GI_3 | 24 | Output | Reserved |
FRNET_PERIPH_GI_4 | 24 | Output | fRSmartComp’s main state information. Default value is 2 (OD state). |