Visible to Intel only — GUID: kba1725891403142
Ixiasoft
4.4.1. DCLSM Blind Window Control Register - DCLSM_BWCR
4.4.2. All Alarms’ Prior Alarms’ Fault Injection Register - ERRCTRL_ALL_ALARMS_PRIOR_AFI
4.4.3. INTREQ Configuration Register - ERRCTRL_INTREQ_CONF
4.4.4. Timeout Deadline and Status Register - ERRCTRL_TIMEOUT
4.4.5. Timeout Acknowledgment Register - ERRCTRL_TIMEOUT_ACK
4.4.6. Enable Key fRSmartComp Control Register - ERRCTRL_ENABLE_KEY
4.4.7. Root Fault Injection Control register - ERRCTRL_ROOT_INJ
4.4.8. Alarm Fault Injection Control register - ERRCTRL_ALARM_INJ
4.4.9. Event Mask Configuration register - ERRCTRL_MASKA and ERRCTRL_MASKB
4.4.10. Alarm Routing Configuration register - ERRCTRL_ROUTA and ERRCTRL_ROUTB
4.4.11. Error Controller PGO LOG Reset Control register - ERRCTRL_PGOLOGRST
4.4.12. PGO0 and PGO4 Configuration registers - ERRCTRL_PGO0 and ERRCTRL_PGO4
4.4.13. FN_MODEIN Control Register - ERRCTRL_FNMODEIN
4.4.14. FN_MODEOUT register - ERRCTRL_FNMODEOUT
4.4.15. All Alarms After Fault Injection - ERRCTRL_FNGIALARMS
4.4.16. Error Controller Context Register - ERRCTRL_FNGICTXT4
4.4.17. CMP Mismatch CONTEXT Registers - ERRCTRL_FNGICMPCTXT0 … ERRCTRL_FNGICMPCTXT3
4.4.18. STATISTICS registers: ERRCTRL_FNGISTAT0 and ERRCTRL_FNGISTAT4
4.4.19. State register - ERRCTRL_FNPERIPHGI4
Visible to Intel only — GUID: kba1725891403142
Ixiasoft
2.5.1.1. Configuring Alarm Severity
fRSmartComp collects and processes all the alarms. They are individually readable and defined with a default severity.
Optionally, each alarm can be routed to one of three outputs on the System Interface (ERROR, WARNING and INFO) according to its degree of severity. The system supervisor can change the setting depending on the specific application and safety requirements.
Each alarm severity is configured as such:
- 2’b00: alarm routed to ERROR
- 2’b01: reserved value
- 2’b10: alarm routed to WARNING
- 2’b11: alarm routed to INFO
You can configure the Alarm Severity through the following interfaces:
Interface | Actions |
---|---|
Configuration Interface |
|
fRNET Interface |
|
The following are the bit field settings to replicate the default alarm severity:
- ALARM 0 to 11 inclusive: 0x5554A8.
- ALARM 12 to 23 inclusive: 0x550055