Visible to Intel only — GUID: wuh1598660155375
Ixiasoft
1. Answers to Top FAQs
2. System Debugging Tools Overview
3. Design Debugging with the Signal Tap Logic Analyzer
4. Quick Design Verification with Signal Probe
5. In-System Debugging Using External Logic Analyzers
6. In-System Modification of Memory and Constants
7. Design Debugging Using In-System Sources and Probes
8. Analyzing and Debugging Designs with System Console
9. Intel® Quartus® Prime Pro Edition User Guide Debug Tools Archives
A. Intel® Quartus® Prime Pro Edition User Guides
2.1. System Debugging Tools Portfolio
2.2. Tools for Monitoring RTL Nodes
2.3. Stimulus-Capable Tools
2.4. Virtual JTAG Interface Intel® FPGA IP
2.5. System-Level Debug Fabric
2.6. SLD JTAG Bridge
2.7. Partial Reconfiguration Design Debugging
2.8. Preserving Signals for Debugging
2.9. System Debugging Tools Overview Revision History
3.1. Signal Tap Logic Analyzer Introduction
3.2. Signal Tap Debugging Flow
3.3. Step 1: Add the Signal Tap Logic Analyzer to the Project
3.4. Step 2: Configure the Signal Tap Logic Analyzer
3.5. Step 3: Compile the Design and Signal Tap Instances
3.6. Step 4: Program the Target Hardware
3.7. Step 5: Run the Signal Tap Logic Analyzer
3.8. Step 6: Analyze Signal Tap Captured Data
3.9. Other Signal Tap Debugging Flows
3.10. Signal Tap Logic Analyzer Design Examples
3.11. Custom State-Based Triggering Flow Examples
3.12. Signal Tap File Templates
3.13. Running the Stand-Alone Version of Signal Tap
3.14. Signal Tap Scripting Support
3.15. Signal Tap File Version Compatibility
3.16. Design Debugging with the Signal Tap Logic Analyzer Revision History
3.4.1. Preserving Signals for Monitoring and Debugging
3.4.2. Preventing Changes that Require Full Recompilation
3.4.3. Specifying the Clock, Sample Depth, and RAM Type
3.4.4. Specifying the Buffer Acquisition Mode
3.4.5. Adding Signals to the Signal Tap Logic Analyzer
3.4.6. Defining Trigger Conditions
3.4.7. Specifying Pipeline Settings
3.4.8. Filtering Relevant Samples
3.4.6.1. Basic Trigger Conditions
3.4.6.2. Nested Trigger Conditions
3.4.6.3. Comparison Trigger Conditions
3.4.6.4. Advanced Trigger Conditions
3.4.6.5. Custom Trigger HDL Object
3.4.6.6. Specify Trigger Position
3.4.6.7. Power-Up Triggers
3.4.6.8. External Triggers
3.4.6.9. Trigger Condition Flow Control
3.4.6.10. Sequential Triggering
3.4.6.11. State-Based Triggering
3.4.6.12. Trigger Lock Mode
3.4.6.11.5.1. <state_label>
3.4.6.11.5.2. <boolean_expression>
3.4.6.11.5.3. <action_list>
3.4.6.11.5.4. Trigger that Skips Clock Cycles after Hitting Condition
3.4.6.11.5.5. Storage Qualification with Post-Fill Count Value Less than m
3.4.6.11.5.6. Resource Manipulation Action
3.4.6.11.5.7. Buffer Control Actions
3.4.6.11.5.8. State Transition Action
3.8.1. Viewing Capture Data Using Segmented Buffers
3.8.2. Viewing Data with Different Acquisition Modes
3.8.3. Creating Mnemonics for Bit Patterns
3.8.4. Locating a Node in the Design
3.8.5. Saving Captured Signal Tap Data
3.8.6. Exporting Captured Signal Tap Data
3.8.7. Creating a Signal Tap List File
3.9.1. Signal Tap and Simulator Integration
3.9.2. Managing Multiple Signal Tap Configurations
3.9.3. Debugging Partial Reconfiguration Designs with Signal Tap
3.9.4. Debugging Block-Based Designs with Signal Tap
3.9.5. Debugging Devices that use Configuration Bitstream Security
3.9.6. Signal Tap Data Capture with the MATLAB* MEX Function
3.9.4.1.1. Partition Boundary Ports Method
3.9.4.1.2. Debug a Core Partition through Partition Boundary Ports
3.9.4.1.3. Export a Core Partition with Partition Boundary Ports
3.9.4.1.4. Signal Tap HDL Instance Method
3.9.4.1.5. Export a Core Partition with Signal Tap HDL Instances
3.9.4.1.6. Debug a Core Partition Exported with Signal Tap HDL Instances
4.1.1. Step 1: Reserve Signal Probe Pins
4.1.2. Step 2: Assign Nodes to Signal Probe Pins
4.1.3. Step 3: Connect the Signal Probe Pin to an Output Pin
4.1.4. Step 4: Compile the Design
4.1.5. (Optional) Step 5: Modify the Signal Probe Pins Assignments
4.1.6. Step 6: Run Fitter-Only Compilation
4.1.7. Step 7: Check Connection Table in Fitter Report
6.1. IP Cores Supporting In System Memory Content Editor
6.2. Debug Flow with the In-System Memory Content Editor
6.3. Enabling Runtime Modification of Instances in the Design
6.4. Programming the Device with the In-System Memory Content Editor
6.5. Loading Memory Instances to the ISMCE
6.6. Monitoring Locations in Memory
6.7. Editing Memory Contents with the Hex Editor Pane
6.8. Importing and Exporting Memory Files
6.9. Access Two or More Devices
6.10. Scripting Support
6.11. In-System Modification of Memory and Constants Revision History
7.1. Hardware and Software Requirements
7.2. Design Flow Using the In-System Sources and Probes Editor
7.3. Compiling the Design
7.4. Running the In-System Sources and Probes Editor
7.5. Tcl interface for the In-System Sources and Probes Editor
7.6. Design Example: Dynamic PLL Reconfiguration
7.7. Design Debugging Using In-System Sources and Probes Revision History
8.1. Introduction to System Console
8.2. Starting System Console
8.3. System Console GUI
8.4. Launching a Toolkit in System Console
8.5. Using System Console Services
8.6. On-Board Intel® FPGA Download Cable II Support
8.7. MATLAB* and Simulink* in a System Verification Flow
8.8. System Console Examples and Tutorials
8.9. Running System Console in Command-Line Mode
8.10. Using System Console Commands
8.11. Using Toolkit Tcl Commands
8.12. Analyzing and Debugging Designs with the System Console Revision History
8.5.1. Locating Available Services
8.5.2. Opening and Closing Services
8.5.3. Using the SLD Service
8.5.4. Using the In-System Sources and Probes Service
8.5.5. Using the Monitor Service
8.5.6. Using the Device Service
8.5.7. Using the Design Service
8.5.8. Using the Bytestream Service
8.5.9. Using the JTAG Debug Service
Visible to Intel only — GUID: wuh1598660155375
Ixiasoft
3.3.2. Creating a Signal Tap Instance by HDL Instantiation
You can create a Signal Tap Instance by HDL instantiation, rather than using the Signal Tap logic analyzer GUI. When you use HDL instantiation, you first parameterize and instantiate the Signal Tap Logic Analyzer Intel FPGA IP in your RTL. Next, you compile the design and IP, and run a Signal Tap analysis using the generated .stp file. Follow these steps to create a Signal Tap instance by HDL instantiation:
Signal Tap Logic Analyzer Intel FPGA IP
- From the Intel® Quartus® Prime IP Catalog (View > IP Catalog), locate and double-click the Signal Tap Logic Analyzer Intel FPGA IP.
- In the New IP Variant dialog box, specify the File Name for your Signal Tap instance, and then click Create. The IP parameter editor displays the available parameter settings for the Signal Tap instance.
- In the parameter editor, specify the Data, Segmented Acquisition, Storage Qualifier, Trigger, and Pipelining parameters, as Signal Tap Intel FPGA IP Parameters describes.
- Click Generate HDL. The parameter editor generates the HDL implementation of the Signal Tap instance according to your specifications.
Figure 24. IP Parameter Editor
- To instantiate the Signal Tap instance in your RTL, click Generate > Show Instantiation Template in the parameter editor. Copy the Instantiation Template contents into your RTL.
Figure 25. Signal Tap Logic Analyzer Intel FPGA IP Instantiation Template
- Run at least the Analysis & Synthesis stage of the Compiler to synthesize the RTL (including Signal Tap instance) by clicking Processing > Start > Start Analysis & Synthesis. Alternatively, you can run full compilation and the Assembler at this point if ready.
- When the Compiler completes, click Create/Update > Create Signal Tap File from Design Instance to create a .stp file for analysis in the Signal Tap logic analyzer GUI.
Figure 26. Create Signal Tap File from Design Instances Dialog BoxNote: If your project contains partial reconfiguration partitions, the PR partitions display in a tree view. Select a partition from the view, and click Create Signal Tap file. The resulting .stp file that generates contains all HDL instances in the corresponding PR partition. The resulting .stp file does not include the instances in any nested partial reconfiguration partition.
- To analyze the Signal Tap instance, click File > Open and select the .stp file. The Signal Tap instance opens in the Signal Tap logic analyzer GUI for analysis. All the fields are read-only, except runtime-configurable trigger conditions.
- Modify any runtime-configurable trigger conditions, as Runtime Reconfigurable Options describes.