1.4.1.4. Disparity Checker

Note: The disparity checker is only used in Interlaken configurations.

The design of the disparity checker is based on the Interlaken protocol specifications. After word synchronization is achieved, the disparity checker monitors the status of the 67th bit of the incoming word and determines whether or not to invert bits [63:0] of the received word.

Table 11.  Interpretation of the MSB in the 67-Bit Payload for Stratix V Devices
MSB Interpretation
0 Bits [63:0] are not inverted; the disparity checker processes the word without modification
1 Bits [63:0] are inverted; the disparity checker inverts the word to achieve the original word before processing it