Intel® Stratix® 10 Configuration User Guide

ID 683762
Date 1/10/2022
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

3.2.9. Active Serial Configuration Software Settings

You must set the parameters in the Device and Pin Options of the Intel® Quartus® Prime software when using the AS configuration scheme.

To set the parameters for AS configuration scheme, complete the following steps:

  1. On the Assignments menu, click Device.
  2. In the Device and Pin Options select the Configuration category.
    1. Select Active Serial x4 from the Configuration scheme drop down menu.
    2. Select Auto or 1.8 V in the Configuration device I/O voltage drop-down list.
    3. Select the AS clock frequency from the Active serial clock source drop-down list.
  3. Click OK to confirm and close the Device and Pin Options.