25.3.3. Watchdog Timer Clocks

Each watchdog timer is connected to the l4_sys_free_clk clock so that timer operation is not dependent on the phase-locked loops (PLLs) in the clock manager and so that it is always running. This independence allows recovery from software that inadvertently programs the PLLs in the clock manager incorrectly.

Table 226.  Watchdog Timer Clocks
Timer System Clock
watchdog0 l4_sys_free_clk