11.4.10.4. CTI-NoC
The CTI is used for receiving triggers from device that can generate triggers and for sending triggers to devices that can receive triggers. This instance of CTI is used exclusively by NoC and allows NoC probe units to send and receive triggers.
Name | Input/Output | Description |
---|---|---|
CTITRIGIN | Input | Trigger In Connected to noc_CTITRIGIN |
TISBYPASSIN | Input | 8’b0000_0000 —Trigger In synchronization bypass (Static value) Enable synchronizers for all 8 inputs. CTI runs off cs_at_clk |
CTITRIGINACK | Output | Trigger In acknowledge Connected to noc_CTITRIGINACK |
Name | Input/Output | Description |
---|---|---|
CTITRIGOUT | Output | Trigger Out Connected to noc_CTITRIGOUT |
CTITRIGOUTACK | Input | Trigger Out acknowledge Connected to noc_CTITRIGOUTACK |
TISBYPASSACK | Input | 8’b0000_0000—Trigger Out acknowledge synchronization bypass (Static value) Enable synchronizers for all 8 inputs |
TIHSBYPASS | Input | 8’b0000_0000—Trigger interface handshake bypass (Static value) Hand shaking is enabled |