Visible to Intel only — GUID: sam1412657311811
Ixiasoft
Visible to Intel only — GUID: sam1412657311811
Ixiasoft
1.3.5. Parameters
Bit | Parameter | Width | Comments |
---|---|---|---|
000 | Reconfiguration trigger conditions (Read Only) | 5 |
The POR value for all bits are 0. |
001 | Illegal Value | ||
010 | Watchdog Timeout Value | 12 | Width of 12 when writing. The 12 bits for writing are the upper 12 bits (left-most or most-significant bits) of the 29-bit Watchdog Timeout Value. When writing parameter data, data_in[11..0] corresponds to the upper 12 bits of the 29-bit Watchdog Timeout Value. For example, to set the Watchdog Timeout Value to 1, write the 12 bits of data_in[11..0] as 12'b000000000001. |
29 | Width of 29 when reading. | ||
011 | Watchdog Enable | 1 | — |
100 | Page Select | 24 or 32 | For the Intel® Quartus® Prime software version 13.1 and later:
For the Intel® Quartus® Prime software version 13.0 and earlier:
|
101 | Configuration Mode (AnF) | 1 | This parameter is set to 1 in application page and is set to 0 in factory page. In remote update mode, this parameter can be read and written. Before loading the application page in remote update mode, Intel® recommends that you set this parameter to 1. The content of the control register cannot be read properly if you fail to do so. |
110 | Illegal Value | ||
111 | Illegal Value |