Intel® Quartus® Prime Standard Edition User Guide: Debug Tools

ID 683552
Date 9/24/2018
Public
Document Table of Contents

5.4.5. Trigger Condition Flow Control

The Trigger Condition Flow allows you to define the relationship between a set of triggering conditions. Signal Tap Logic Analyzer Signal Configuration pane offers two flow control mechanisms for organizing trigger conditions:
  • Sequential Triggering—default triggering flow. Sequential triggering allows you to define up to 10 triggering levels that must be satisfied before the acquisition buffer finishes capturing.
  • State-Based Triggering—gives the greatest control over your acquisition buffer. Custom-based triggering allows you to organize trigger conditions into states based on a conditional flow that you define.

You can use sequential or state based triggering with either a segmented or a non-segmented buffer.