5.5.6.2. Signal Tap Logic Using Critical Resources

If your design is resource constrained, follow these tips to reduce the logic or memory the Signal Tap Logic Analyzer uses:
  • Disable runtime configurable options—Disabling runtime configurability for advanced trigger conditions or runtime configurable options in the State-based triggering flow results in fewer LEs.
  • Minimize the number of segments in the acquisition buffer—You can reduce the logic resources that the Signal Tap Logic Analyzer uses if you limit the segments in your sampling buffer