Quartus® Prime Pro Edition User Guide: Getting Started

ID 683463
Date 9/30/2024
Public
Document Table of Contents

6.1.2.7. Removing Unsupported Feature Assignments

The Quartus® Prime Pro Edition software does not support some feature assignments that other Quartus software products support. Remove the following unsupported feature assignments from other Quartus software product .qsf files for migration to the Quartus® Prime Pro Edition software.
  • Incremental Compilation (partitions)—The current version of the Quartus® Prime Pro Edition software does not support Quartus® Prime Standard Edition incremental compilation. Remove all incremental compilation feature assignments from other Quartus software product .qsf files before migration.
  • Quartus® Prime Standard Edition Physical synthesis assignments. Quartus® Prime Pro Edition software does not support Quartus® Prime Standard Edition Physical synthesis assignments. Remove any of the following assignments from the .qsf file or design RTL (instance assignments) before migration.
PHYSICAL_SYNTHESIS_COMBO_LOGIC_FOR_AREA
    PHYSICAL_SYNTHESIS_COMBO_LOGIC
    PHYSICAL_SYNTHESIS_REGISTER_DUPLICATION
    PHYSICAL_SYNTHESIS_REGISTER_RETIMING
    PHYSICAL_SYNTHESIS_ASYNCHRONOUS_SIGNAL_PIPELINING
    PHYSICAL_SYNTHESIS_MAP_LOGIC_TO_MEMORY_FOR_AREA 
Note: If you open a Quartus® Prime Standard Edition software project in the Quartus® Prime Pro Edition software, and that project contains unsupported junction temperature setting values, you can modify these settings by clicking Assignments > Settings > Operating Settings and Conditions > Temperature. Click OK, and then click Yes when prompted to update the values.