The following table lists the parameters for the SDI Audio Extract IP core.

Table 5.  SDI Audio Extract Parameters

Parameter

Value

Description

Async Audio Interface On or Off

Turn on to enable the Asynchronous output.

This mode supports an audio clock equal to or higher than 64 × sample rate.

Parallel Audio Interface On or Off

Turn on to send AES data in parallel mode with a 32-bit parallel interface.

Requires Async Audio Interface to be turned on.

The actual audio sample rate is specified for serial data transmission. The equivalent audio sample rate in parallel mode matches the actual audio sample rate.

Include SD-SDI 24-bit support

On or Off

Enables the extra logic to recover the EDP ancillary packets from SD-SDI inputs.

Channel status RAM On or Off

Turn on to store the received channel status data.

Include error checking On or Off

Turn on to enable extra error-checking logic to use the error status register.

Include status register On or Off

Turn on to enable extra logic to report the audio FIFO status on the fifo_status port or register.

Include clock On or Off

Turn on to enable the logic to recover both a sample rate clock and a 64 × sample rate clock.

With HD-SDI inputs, the core generates the output by using the embedded clock phase information.

With SD-SDI inputs, the core generates this output by using the counters running on the 27-MHz video clock. This generation limits the SD-SDI embedded audio to being synchronous to the video.

Include Avalon-ST interface On or Off

Turn on to include the SDI Clocked Audio Input IP core.

When you turn on this parameter, the Avalon-ST interface signals appear at the top level. Otherwise, the audio input signals appear at the top level.

Include Avalon-MM control interface On or Off

Turn on to include the Avalon-MM control interface.