FIR II IP Core: User Guide

ID 683208
Date 6/12/2020
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

3.2. FIR II IP Core Coefficient Settings

Table 9.  Coefficient Settings Parameters
Parameter Value Description
Coefficient Options
Symmetry Mode Non Symmetry

Symmetrical

Anti-Symmetrical

Specifies whether your filter design uses non-symmetric, symmetric, or anti-symmetric coefficients. The default value is Non Symmetry.
L-th Band Filter All taps

Half band

3rd–5th

Specifies the appropriate L-band Nyquist filters. Every Lth coefficient of these filters is zero, counting out from the center tap.
Coefficient Scaling Auto

None

Specifies the coefficient scaling mode. Select Auto to apply a scaling factor in which the maximum coefficient value equals the maximum possible value for a given number of bits. Select None to read in pre-scaled integer values for the coefficients and disable scaling.
Coefficient Data Type Signed Binary

Signed Fractional Binary

Specifies the coefficient input data type. Select Signed Fractional Binary to monitor which bits are preserved and which bits are removed during the filtering process.
Coefficient Width 2–32 Specifies the width of the coefficients. The default value is 8 bits.