Altera® Quartus® Prime Standard Edition Settings File Reference Manual

ID 683084
Date 5/08/2017
Public
Document Table of Contents

1.3.43. RELEASE_CLEARS_BEFORE_TRI_STATES

Directs the device to release the clear signal on registered logic cells and I/O cells before releasing the output enable override on tri-state buffers. If this option is turned off, the output enable signals are released before the clear overrides are released.

Old Name

Release clears before tri-states

Type

Boolean

Device Support

  • Arria 10
  • Arria GX
  • Arria II GX
  • Arria II GZ
  • Arria V
  • Arria V GZ
  • Cyclone
  • Cyclone 10 LP
  • Cyclone II
  • Cyclone III
  • Cyclone III LS
  • Cyclone IV E
  • Cyclone IV GX
  • Cyclone V
  • A
  • E
  • HardCopy II
  • HardCopy III
  • HardCopy IV
  • MAX 10
  • Mercury
  • Stratix
  • Stratix GX
  • Stratix II
  • Stratix II GX
  • Stratix III
  • Stratix IV
  • Stratix V

Notes

This assignment is included in the Fitter report.

Syntax


		set_global_assignment -name RELEASE_CLEARS_BEFORE_TRI_STATES <value>
	

Default Value

Off