1.8.30. EDA_NATIVELINK_PORTABLE_FILE_PATHS

Specifies that the file paths in the generated third-party EDA tool command scripts should be written out using relative paths for design and testbench files, and by using a variable to refer to Quartus Prime simulation library path.

Type

Boolean

Device Support

This setting can be used in projects targeting any Altera device family.

Notes

This assignment is included in the Fitter report.

Syntax


		set_global_assignment -name EDA_NATIVELINK_PORTABLE_FILE_PATHS -section_id <section identifier> <value>
		set_global_assignment -name EDA_NATIVELINK_PORTABLE_FILE_PATHS -entity <entity name> -section_id <section identifier> <value>
	

Default Value