1.5.5. DEFAULT_HOLD_MULTICYCLE
Determines the default hold multicycle. The 'Same as Multicycle' setting ensures that the signal is latched on the final edge only. The 'One' setting assumes that the design can latch on any edge, up to and including the final edge. The 'Same as Multicycle' setting will give fewer hold time violation warnings. The 'One' setting is more restrictive, but it is the default setting for the TimeQuest Timing Analyzer and other third-party timing analyzers. This setting can be overridden on specific nodes with the Hold Multicycle option.
Type
Enumeration
Values
- One
- Same as Multicycle
Device Support
This setting can be used in projects targeting any Altera device family.
Notes
None
Syntax
set_global_assignment -name DEFAULT_HOLD_MULTICYCLE <value>
Default Value
Same as Multicycle
Example
set_global_assignment -name default_hold_multicycle "Same as Multicycle"
set_global_assignment -name default_hold_multicycle "One"
See Also