Intel® Stratix® 10 Hard Processor System Remote System Update User Guide

ID 683021
Date 11/10/2021
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

5.1. SDM RSU Support

Besides implementing the actual RSU configuration flow, the SDM offers commands to interact with RSU:
  • Get the flash address of the currently running image.
  • Get details on the errors that occurred when trying to load an image which failed.
  • Clear the sticky error information to be able to record new error information.
  • Get the locations of SPTs.
  • Load a specific image.
  • Report the state of HPS software.
  • Query the value of the current retry counter.
  • Reset the value of the current retry counter.

The SDM commands need to be called from EL3, the highest execution level on Cortex-A53.

The SDM commands are not publicly documented. Full support is offered for accessing the relevant services from both U-Boot and LIBRSU.