Visible to Intel only — GUID: owp1540272329737
Ixiasoft
1. Overview
2. Use Cases
3. Quad SPI Flash Layout
4. Intel® Quartus® Prime Software and Tool Support
5. Software Support
6. Flash Corruption - Detection and Recovery
7. Remote System Update Example
8. Version Compatibility Considerations
9. Using RSU with HPS First
A. Configuration Flow Diagrams
B. RSU Status and Error Codes
C. U-Boot RSU Reference Information
D. LIBRSU Reference Information
E. Combined Application Images
10. Document Revision History for the Intel® Stratix® 10 SoC Remote System Update User Guide
2.1. Manufacturing
2.2. Application Image Boot
2.3. Factory Image Boot
2.4. Modifying the List of Application Images
2.5. Querying RSU Status
2.6. Loading a Specific Image
2.7. Protected Access to Flash
2.8. Remote System Update Watchdog
2.9. RSU Notify
2.10. Updating the Factory Image
2.11. Updating the Decision Firmware
2.12. Retrying when Configuration Fails
2.13. Querying the Decision Firmware Version
7.2.1. Setting up the Environment
7.2.2. Building the Hardware Projects
7.2.3. Building Arm* Trusted Firmware
7.2.4. Building U-Boot
7.2.5. Creating the Initial Flash Image
7.2.6. Creating the Application Image
7.2.7. Creating the Factory Update Image
7.2.8. Creating the Decision Firmware Update Image
7.2.9. Building Linux*
7.2.10. Building ZLIB
7.2.11. Building LIBRSU and RSU Client
7.2.12. Building the Root File System
7.2.13. Building the SD Card
C.6.1. rsu_init
C.6.2. rsu_exit
C.6.3. rsu_slot_count
C.6.4. rsu_slot_by_name
C.6.5. rsu_slot_get_info
C.6.6. rsu_slot_size
C.6.7. rsu_slot_priority
C.6.8. rsu_slot_erase
C.6.9. rsu_slot_program_buf
C.6.10. rsu_slot_program_factory_update_buf
C.6.11. rsu_slot_program_buf_raw
C.6.12. rsu_slot_verify_buf
C.6.13. rsu_slot_verify_buf_raw
C.6.14. rsu_slot_enable
C.6.15. rsu_slot_disable
C.6.16. rsu_slot_load
C.6.17. rsu_slot_load_factory
C.6.18. rsu_slot_rename
C.6.19. rsu_slot_delete
C.6.20. rsu_slot_create
C.6.21. rsu_status_log
C.6.22. rsu_notify
C.6.23. rsu_clear_error_status
C.6.24. rsu_reset_retry_counter
C.6.25. rsu_dcmf_version
C.6.26. rsu_max_retry
C.6.27. rsu_dcmf_status
C.6.28. rsu_create_empty_cpb
C.6.29. rsu_restore_cpb
C.6.30. rsu_save_cpb
C.6.31. rsu_restore_spt
C.6.32. rsu_save_spt
C.6.33. rsu_running_factory
C.7.1. dtb
C.7.2. list
C.7.3. slot_by_name
C.7.4. slot_count
C.7.5. slot_disable
C.7.6. slot_enable
C.7.7. slot_erase
C.7.8. slot_get_info
C.7.9. slot_load
C.7.10. slot_load_factory
C.7.11. slot_priority
C.7.12. slot_program_buf
C.7.13. slot_program_buf_raw
C.7.14. slot_program_factory_update_buf
C.7.15. slot_rename
C.7.16. slot_delete
C.7.17. slot_create
C.7.18. slot_size
C.7.19. slot_verify_buf
C.7.20. slot_verify_buf_raw
C.7.21. status_log
C.7.22. update
C.7.23. notify
C.7.24. clear_error_status
C.7.25. reset_retry_counter
C.7.26. display_dcmf_version
C.7.27. display_dcmf_status
C.7.28. display_max_retry
C.7.29. restore_spt
C.7.30. save_spt
C.7.31. create_empty_cpb
C.7.32. restore_cpb
C.7.33. save_cpb
C.7.34. check_running_factory
D.6.1. librsu_init
D.6.2. librsu_exit
D.6.3. rsu_slot_count
D.6.4. rsu_slot_by_name
D.6.5. rsu_slot_get_info
D.6.6. rsu_slot_size
D.6.7. rsu_slot_priority
D.6.8. rsu_slot_erase
D.6.9. rsu_slot_program_buf
D.6.10. rsu_slot_program_factory_update_buf
D.6.11. rsu_slot_program_file
D.6.12. rsu_slot_program_factory_update_file
D.6.13. rsu_slot_program_buf_raw
D.6.14. rsu_slot_program_file_raw
D.6.15. rsu_slot_verify_buf
D.6.16. rsu_slot_verify_file
D.6.17. rsu_slot_verify_buf_raw
D.6.18. rsu_slot_verify_file_raw
D.6.19. rsu_slot_program_callback
D.6.20. rsu_slot_program_callback_raw
D.6.21. rsu_slot_verify_callback
D.6.22. rsu_slot_verify_callback_raw
D.6.23. rsu_slot_copy_to_file
D.6.24. rsu_slot_enable
D.6.25. rsu_slot_disable
D.6.26. rsu_slot_load_after_reboot
D.6.27. rsu_slot_load_factory_after_reboot
D.6.28. rsu_slot_rename
D.6.29. rsu_slot_delete
D.6.30. rsu_slot_create
D.6.31. rsu_status_log
D.6.32. rsu_notify
D.6.33. rsu_clear_error_status
D.6.34. rsu_reset_retry_counter
D.6.35. rsu_dcmf_version
D.6.36. rsu_max_retry
D.6.37. rsu_dcmf_status
D.6.38. rsu_save_spt
D.6.39. rsu_restore_spt
D.6.40. rsu_save_cpb
D.6.41. rsu_create_empty_cpb
D.6.42. rsu_restore_cpb
D.6.43. rsu_running_factory
D.7.1. count
D.7.2. list
D.7.3. size
D.7.4. priority
D.7.5. enable
D.7.6. disable
D.7.7. request
D.7.8. request-factory
D.7.9. erase
D.7.10. add
D.7.11. add-factory-update
D.7.12. add-raw
D.7.13. verify
D.7.14. verify-raw
D.7.15. copy
D.7.16. log
D.7.17. notify
D.7.18. clear-error-status
D.7.19. reset-retry-counter
D.7.20. display-dcmf-version
D.7.21. display-dcmf-status
D.7.22. display-max-retry
D.7.23. create-slot
D.7.24. delete-slot
D.7.25. restore-spt
D.7.26. save-spt
D.7.27. create-empty-cpb
D.7.28. restore-cpb
D.7.29. save-cpb
D.7.30. check-running-factory
D.7.31. help
Visible to Intel only — GUID: owp1540272329737
Ixiasoft
3.1.3. RSU Image Layout – Your Perspective
The sub-partition table (SPT) is used for managing the allocation of the quad SPI flash.
The Intel® Quartus® Prime Programming File Generator creates the SPT when creating the initial manufacturing image. To ensure reliable operation, the Programming File Generator creates two copies of the sub-partition table and the configuration pointer block, SPT0 and SPT1 and CPB0 and CPB1
The initial RSU image stored in flash typically contains the following partitions:
Sub-partition Name | Contents |
---|---|
BOOT_INFO | Decision firmware and decision firmware data |
FACTORY_IMAGE | Factory Image |
SPT0 | Sub-partition table 0 |
SPT1 | Sub-partition table 1 |
CPB0 | Pointer block 0 |
CPB1 | Pointer block 1 |
P1 | Application image 1 |
P2 | Application image 2 |
Figure 5. RSU Image Layout - Your PerspectiveIn this figure:
- SPT0 and SPT1 point to everything:
- BOOT_INFO
- Factory Image
- Pointer Block 0 and Pointer Block 1
- All Application Images
- Pointer Block 0 and Pointer Block 1 point to all Application Images
To summarize, your view of flash memory is different from SDM view in two ways:
- You do not need to know the addresses of the decision firmware, decision firmware data, and factory image.
- You have access to the sub-partition tables. The sub-partition tables provide access to the data structures required for remote system update.
Related Information