4.8.5. PTP Status Interface
The PTP status interface indicates when the PTP timestamp logic is ready to use.
Signal Name | Width | Description |
---|---|---|
o_tx_ptp_offset_data_valid | 1 | TX PTP Offset Data is Valid 1: Indicates the following PTP offset data is ready to read from AVMM register:
|
o_rx_ptp_offset_data_valid | 1 | RX PTP Offset Data is Valid
1: Indicates the following PTP offset data is ready to read from AVMM register:
|
o_tx_ptp_ready | 1 | TX PTP Logic is ready for use 1: Indicates that PTP for TX data path is fully functional, TX Egress Timestamp is valid within supported accuracy range. User could send PTP packet to TX interface. |
o_rx_ptp_ready | 1 | RX PTP Logic is ready for use 1: Indicates that PTP for RX data path is fully functional, RX Ingress Timestamp is valid within supported accuracy range. |