Intel Agilex® 7 General-Purpose I/O User Guide: F-Series and I-Series

ID 683780
Date 4/19/2023
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

2.4.1.1.2. RT OCT

RT OCT with calibration is available only for input and bidirectional pins. Output pins do not support RT OCT with calibration.
  • The RT OCT calibration circuit compares the total impedance of the I/O buffer to the external resistor connected to the RZQ pin.
  • During calibration, the circuit continuously alters the impedance of the I/O buffer until the value reaches the target impedance, which is a predetermined ratio to the reference resistance.
  • The calibration occurs at the end of the device configuration. When the calibration circuit finds the correct impedance, the circuit powers down and stops changing the characteristics of the drivers.
  • You may trigger recalibration during user mode.
Table 12.  Selectable I/O Standards for RT OCT with CalibrationThis table lists the output termination settings for calibrated OCT on different I/O standards.
I/O Standard RT OCT with Calibration (Ω)
SSTL-12 50, 60
POD12 50, 60
HSTL-12 50, 60
Differential SSTL-12 50, 60
Differential POD12 50, 60
Differential HSTL-12 50, 60