Floating-Point IP Cores User Guide

ID 683750
Date 7/31/2024
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

9.7. Parameters

Table 57.  ALTFP_INV_SQRT IP core Parameters
Parameter Name Type Required Description
WIDTH_EXP Integer Yes Specifies the precision of the exponent. If this parameter is not specified, the default is 8. The bias of the exponent is always set to 2 (WIDTH_EXP -1) -1, that is, 127 for the single-precision format and 1023 for the double-precision format. The value of the WIDTH_EXP parameter must be 8 for the single-precision format, 11 for the double-precision format, and a minimum of 11 for the single-extended precision format. The value of the WIDTH_EXP parameter must be less than the value of the WIDTH_MAN parameter, and the sum of the WIDTH_EXP and WIDTH_MAN parameters must be less than 64.
WIDTH_MAN Integer Yes Specifies the value of the mantissa. If this parameter is not specified, the default is 23. When the WIDTH_EXP parameter is 8 and the floating-point format is single-precision, the WIDTH_MAN parameter value must be 23. Otherwise, the value of the WIDTH_MAN parameter must be a minimum of 31. The value of the WIDTH_MAN parameter must be greater than the value of the WIDTH_EXP parameter. The sum of the WIDTH_EXP and WIDTH_MAN parameters must be less than 64.
PIPELINE Integer Yes Specifies the amount of latency, expressed in clock cycles, used in the ALTFP_INV_SQRT IP core. Create the ALTFP_INV_SQRT IP core to calculate the value for this parameter.
ROUNDING String No Specifies the rounding mode. The default value is TO_NEAREST. Other rounding modes are not supported.