Agilex™ 7 Configuration User Guide

ID 683673
Date 11/04/2024
Public
Document Table of Contents

3.2.4. AS Configuration Timing Parameters

Figure 45. AS Configuration Serial Output Timing Diagram
Figure 46. AS Configuration Serial Input Timing Diagram
Table 39.  Text_delay as a Function of AS_CLK Frequency
Symbol Configuration Clock Source Frequency Min (ns) Max (ns)
Text_delay Internal Oscillator 115 MHz 0 20
77 MHz 0 20
58 MHz 0 20
25 MHz 0 24
OSC_CLK_1 166 MHz 0 13.5
125 Mhz 0 18
100 MHz 0 24
71.5 MHz 0 35
50 MHz 0 24
25 MHz 0 24
Note: For more information about the timing parameters, refer to the Agilex™ 7 Device Datasheet.