Error Code | Invalid Condition | Solution |
---|---|---|
0x80000000 | Selected temperature sensor channel is currently inactive. | Ensure that the tile where the TSD is located is actively in use. |
0x80000001 | Selected temperature sensor channel returned a value that is not the latest reading. | Retrieve the temperature reading again |
0x80000002 | Selected temperature sensor channel is invalid for the device. | Ignore the returned data because the temperature sensor channel location is invalid |
0x80000003 | System is corrupted or failed to respond | Contact Intel FPGA support |
0x80000004 | ||
0x80000005 | Communication mechanism is busy | Retrieve the temperature reading again |